{"id":1818,"date":"2024-01-29T14:02:10","date_gmt":"2024-01-29T13:02:10","guid":{"rendered":"https:\/\/www.kowotest.de\/duplex-plate-phantom\/"},"modified":"2024-05-17T13:24:05","modified_gmt":"2024-05-17T11:24:05","slug":"duplex-plate-phantom","status":"publish","type":"page","link":"https:\/\/www.kowotest.de\/en\/duplex-plate-phantom\/","title":{"rendered":"Duplex Plate Phantom"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1703690328020{background-color: rgba(140,150,157,0.2) !important;*background-color: rgb(140,150,157) !important;}&#8221; conditional_render=&#8221;%5B%7B%22value_role%22%3A%22administrator%22%7D%5D&#8221;][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_column_text]<\/p>\n<h3><span style=\"color: #005eb8;\"><strong><span style=\"font-size: 26px;\">DUPLEX PLATE PHANTOM<\/span><\/strong><\/span><\/h3>\n<p>[\/vc_column_text][vc_column_text]<span style=\"color: #8c969d;\"><strong>Article No.: 11 0017X<\/strong><\/span><\/p>\n<p><span style=\"color: #8c969d;\">Heavy Metal &#8211; HM<br \/>\nLight Metal &#8211; LM<br \/>\naccording to ASTM E2737<\/span><\/p>\n<p><span style=\"color: #8c969d;\">Duplex Plate Phantom Type 2<br \/>\nfor Perfomance Evaluation<br \/>\nand Long-Term-Stability Tests of DDAs<\/span>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_gallery interval=&#8221;3&#8243; images=&#8221;1558,1559,1560,1561&#8243; img_size=&#8221;full&#8221; onclick=&#8221;img_link_large&#8221; custom_links_target=&#8221;_blank&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][vc_accordion active_tab=&#8221;1&#8243; collapsible=&#8221;yes&#8221; type=&#8221;custom&#8221; skin=&#8221;light&#8221;][vc_accordion_tab title=&#8221;Description&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner][vc_column_text css=&#8221;&#8221;]<\/p>\n<h4>Test Phantom for Long-Term Stability Tests of DDA Systems (DR)<\/h4>\n<p>The Type 2 Duplex Plate Phantom enables to test relevant parameters of DDA systems like Basic Spatial Resolution, Contrast Sensitivity, SNR and Signal Level for initial performance evaluation and long-term stability. These test required and described in detail in ASTM E2737 have to be performed periodically for checking process control and lang-term stability[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=&#8221;Specification&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<table style=\"height: 352px;\" width=\"776\">\n<tbody>\n<tr>\n<td width=\"32\"><\/td>\n<td width=\"188\">IQI, Gauge<\/td>\n<td width=\"230\">Test, Check<\/td>\n<\/tr>\n<tr>\n<td>A<\/td>\n<td>Base Plate &#8211; thin<\/td>\n<td>HM 5 mm \/ LM 12 mm<\/td>\n<\/tr>\n<tr>\n<td>B<\/td>\n<td>Top Plate &#8211; thick<\/td>\n<td>HM 15 mm \/ LM 38 mm<\/td>\n<\/tr>\n<tr>\n<td>C<\/td>\n<td>Hole Type IQI &#8211; .SS 25 \/ AL .50<\/td>\n<td>Contrast Sensitivity (edge or hole)<\/td>\n<\/tr>\n<tr>\n<td>D<\/td>\n<td>Hole Type IQI &#8211; SS .81 \/ AL 2.0<\/td>\n<td>Contrast Sensitivity (edge or hole)<\/td>\n<\/tr>\n<tr>\n<td>E<\/td>\n<td>ROIs &#8211; Thin Plate<\/td>\n<td>Signal to Noise Ratio, Signal Level<\/td>\n<\/tr>\n<tr>\n<td>F<\/td>\n<td>ROIs &#8211; Thick Plate<\/td>\n<td>Signal to Noise Ratio, Signal Level<\/td>\n<\/tr>\n<tr>\n<td>G<\/td>\n<td>Duplex Wire Type IQI<\/td>\n<td>Basic Spatial Resolution, Unsharpness<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][vc_column_text]<\/p>\n<table style=\"height: 72px;\" width=\"783\">\n<tbody>\n<tr>\n<td width=\"32\"><\/td>\n<td width=\"188\">Dimensions:<\/td>\n<td width=\"230\">400 x 300 x 15 \/ 38 mm<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td>15.75 x 11.81 x 0.59 \/ 1.50 inch<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][vc_column_text css=&#8221;&#8221;]<strong>Advantages of Type 2 compared to Type 1 Duplex Plate Phantom<\/strong><\/p>\n<p><strong>Hole Type IQI on top plate is located in the center of the plate:<\/strong><br \/>\nLow scatter radiation and much lower gradient on the IQI<br \/>\nfor improved repeatability of contrast sensitivity tests<\/p>\n<p><strong>Free areas beside long side of the Hole Type IQI:<\/strong><br \/>\nAllowing contrast sensitivity evaluation also at the edge of the IQI<br \/>\nimproved repeatability compared to evaluation at the holes of IQI<\/p>\n<p><strong>Region of Interest (ROI) on top plate close to Hole Type IQI:<\/strong><br \/>\nLowest gradient in ROI for improved repeatability on SNR and<br \/>\nSignal Level tests<\/p>\n<p><strong>Cut-outs in plastics for ROIs:<\/strong><br \/>\nROIs clearly visible on the X-ray image. Easier evaluation<\/p>\n<p><strong>Two Duplex Wire Type IQIs can be inserted:<\/strong><br \/>\nPortrait and landscape axis can be evaluated in one image<\/p>\n<p><strong>Duplex Wire Type IQIs can be removed:<\/strong><br \/>\nUse for other applications possible[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=&#8221;Types&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text]<strong>Types:<\/strong>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_column_text]<strong>Article No.:<\/strong>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text]Duplex Plate Phantom Type 2 Heavy Metal (HM) in wooden case<br \/>\nComplete with Hole Type IQI ASTM E1742 &#8211; SS size .25 and .81<br \/>\nTest Certificates, Declaration of Conformity[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_column_text]11 00177[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text]Duplex Plate Phantom Type 2 Light Metal (LM) in wooden case<br \/>\nComplete with Hole Type IQI ASTM E1742 &#8211; AL size .50 and 2.0<br \/>\nTest Certificates, Declaration of Conformity[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_column_text]11 00178[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text]Optional:[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/3&#8243;][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text]Holder for Duplex Plate Phantom Type 2, stainless steel<br \/>\nfor clamping and easy positioning of both versions &#8211; HM and LM[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_column_text]11 00179[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text]Duplex Wire Type IQI acc. to ASTM E2002, ISO 13232-5 &#8211; D13<br \/>\nDuplex Wire Type IQIs not included but required.[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_column_text]11 00155[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=&#8221;Accessories&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner][vc_column_text]You can find accessories on the leaflet[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=&#8221;Leaflets&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner][vc_column_text css=&#8221;&#8221;]leaflet German:<br \/>\nleaflet English: <a href=\"https:\/\/www.kowotest.de\/wp-content\/uploads\/2024\/05\/Duplex-Plate-Phantom_LM_HM_02_EN.pdf\">DUPLEX PLATE PHANTOM<\/a>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][\/vc_accordion][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1703690328020{background-color: rgba(140,150,157,0.2) !important;*background-color: rgb(140,150,157) !important;}&#8221; conditional_render=&#8221;%5B%7B%22value_role%22%3A%22administrator%22%7D%5D&#8221;][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_column_text] DUPLEX PLATE PHANTOM [\/vc_column_text][vc_column_text]Article No.: 11 0017X Heavy Metal &#8211; HM Light Metal &#8211; LM according to ASTM E2737 Duplex Plate Phantom Type 2 for Perfomance Evaluation and Long-Term-Stability Tests of DDAs[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_gallery interval=&#8221;3&#8243; images=&#8221;1558,1559,1560,1561&#8243; img_size=&#8221;full&#8221; onclick=&#8221;img_link_large&#8221; custom_links_target=&#8221;_blank&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][vc_accordion active_tab=&#8221;1&#8243; collapsible=&#8221;yes&#8221; type=&#8221;custom&#8221; skin=&#8221;light&#8221;][vc_accordion_tab title=&#8221;Description&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner][vc_column_text [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1818","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/pages\/1818","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/comments?post=1818"}],"version-history":[{"count":10,"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/pages\/1818\/revisions"}],"predecessor-version":[{"id":2402,"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/pages\/1818\/revisions\/2402"}],"wp:attachment":[{"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/media?parent=1818"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}