{"id":1809,"date":"2024-01-13T18:21:28","date_gmt":"2024-01-13T17:21:28","guid":{"rendered":"https:\/\/www.kowotest.de\/koworase-x\/"},"modified":"2024-05-25T13:43:53","modified_gmt":"2024-05-25T11:43:53","slug":"koworase-x","status":"publish","type":"page","link":"https:\/\/www.kowotest.de\/en\/koworase-x\/","title":{"rendered":"KOWORASE X"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1703690328020{background-color: rgba(140,150,157,0.2) !important;*background-color: rgb(140,150,157) !important;}&#8221; conditional_render=&#8221;%5B%7B%22value_role%22%3A%22administrator%22%7D%5D&#8221;][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_column_text]<\/p>\n<h3><span style=\"color: #005eb8;\"><strong><span style=\"font-size: 26px;\">KOWORASE X<\/span><\/strong><\/span><\/h3>\n<p>[\/vc_column_text][vc_column_text css=&#8221;&#8221;]<span style=\"color: #8c969d;\"><strong>Article No.: 12 390XX<br \/>\n<\/strong><\/span><\/p>\n<p><span style=\"color: #8c969d;\">Erase device<br \/>\nfor CR Imaging Plates (IP)<\/span><\/p>\n<p><span style=\"color: #8c969d;\">2-Phase external cleaning of even highly stressed CR Imaging Plates to Erasure and Burn-In levels<br \/>\nrequested in ASTM E2445<\/span>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_gallery interval=&#8221;3&#8243; images=&#8221;2473,2471&#8243; img_size=&#8221;full&#8221; onclick=&#8221;img_link_large&#8221; custom_links_target=&#8221;_blank&#8221; css=&#8221;&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][vc_accordion active_tab=&#8221;1&#8243; collapsible=&#8221;yes&#8221; type=&#8221;custom&#8221; skin=&#8221;light&#8221;][vc_accordion_tab title=&#8221;Discription&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner][vc_column_text css=&#8221;&#8221;]<\/p>\n<h4>KOWORASE X Erase device for CR Imaging Pl ates (IP)<\/h4>\n<p>The KOWORASE X is a highly efficient tool for external erasing of CR imaging plates (IP).<\/p>\n<p>Due to the 2-phase cleaning process even highly stressed imaging plates<br \/>\ncan be recovered to performance levels requested in ASTM E2445 for both tests \u2013 Erasure and Burn-In (\u2264 2% PV or nonvisible).<br \/>\nEven so-called Ghost Images or Burn-Ins can be erased satisfactory &#8211; Ghost Images or Burn-Ins<br \/>\nare artefacts which are nonvisible after erasure but become visible on image of<br \/>\nfollowing exposure.<br \/>\nIn phase 1 the imaging plate is exposed to complete saturation (ca. 65,000 grey values) with UV-light<br \/>\nwhile in phase 2 imaging plate is erased with LED-light to ca. 90 grey values.<br \/>\nTotal time for an erase process is between 3 and 6 minutes dependent on condition (number of exposures),<br \/>\nintensity of burn-in and age of imaging plate.<\/p>\n<p><strong>Use of KOWORASE X:<\/strong><br \/>\nOpening drawer, inserting imaging plates on drawer, closing drawer, starting cleaning process,<br \/>\nremoving imaging plates when process is finished, Imaging plates are ready for new excellent X-ray exposures.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=&#8221;Specification&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text css=&#8221;&#8221;]Housing :<br \/>\nDrawer:<br \/>\nActive Erasure Area:<br \/>\nImaging Plates (IP) :<br \/>\n(max. possible IPs<br \/>\nper erasing process<br \/>\nexemplary)[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text css=&#8221;&#8221;]stainless steel<br \/>\n500 x 400 mm (W x D)<br \/>\n490 x 370 mm (W x D) *)<br \/>\n1x 14 x 17 inch (35 x 43 cm)<br \/>\n2x 15 x 48 cm<br \/>\n3x 10 x 48 cm[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text css=&#8221;&#8221;]Light Sources:<br \/>\nphase 1 &#8211; exposure :<br \/>\nlifetime\/ cycles:<br \/>\nphase 2 &#8211; erasure:<br \/>\nlifetime\/ cycles:<br \/>\nController:<br \/>\nPower Supply:<br \/>\nDimensions:<br \/>\nWeight unit:[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_empty_space height=&#8221;23px&#8221;][vc_column_text css=&#8221;&#8221;]UV-CCFL 250 nm \u2013 40 W<br \/>\n25.000 h \u2248 500.000<br \/>\nLED 6500 K \u2013 80 W<br \/>\n30.000 h \u2248 500.000<br \/>\nTI484801 &#8211; Dual-Prozess-Timer<br \/>\n90 &#8230; 260 V \/ 47 &#8230; 63 Hz \/ 90 W<br \/>\n58 x 48 x 39 cm (W x D x H)<br \/>\n29 kg[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner][vc_column_text css=&#8221;&#8221;]*) ilms longer 48 cm must be erased in more steps by pushing thru side openings<br \/>\nIn-\/ outfeed tables can be mounted left and right at the side openings in the housing[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=&#8221;Types&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text css=&#8221;&#8221;]<strong>Typ<\/strong><strong>:<\/strong>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text css=&#8221;&#8221;]<strong>Article No.:<\/strong>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text css=&#8221;&#8221;]KOWORASE X Erase Device<br \/>\nPower cupply cable<br \/>\nCertificate of Conformity[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]12 39050[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=&#8221;Accessories&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner][vc_column_text css=&#8221;&#8221;]You can find accessories on the leaflet[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=&#8221;Leaflets&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner][vc_column_text css=&#8221;&#8221;]leaflet German: <a href=\"https:\/\/www.kowotest.de\/wp-content\/uploads\/2024\/05\/KOWORASE-X_01_DE.pdf\">KOWORASE X<\/a><br \/>\nleaflet English: <a href=\"https:\/\/www.kowotest.de\/wp-content\/uploads\/2024\/05\/KOWORASE-X_01_EN.pdf\">KOWORASE X<\/a>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][\/vc_accordion][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1703690328020{background-color: rgba(140,150,157,0.2) !important;*background-color: rgb(140,150,157) !important;}&#8221; conditional_render=&#8221;%5B%7B%22value_role%22%3A%22administrator%22%7D%5D&#8221;][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_column_text] KOWORASE X [\/vc_column_text][vc_column_text css=&#8221;&#8221;]Article No.: 12 390XX Erase device for CR Imaging Plates (IP) 2-Phase external cleaning of even highly stressed CR Imaging Plates to Erasure and Burn-In levels requested in ASTM E2445[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_gallery interval=&#8221;3&#8243; images=&#8221;2473,2471&#8243; img_size=&#8221;full&#8221; onclick=&#8221;img_link_large&#8221; custom_links_target=&#8221;_blank&#8221; css=&#8221;&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][vc_accordion active_tab=&#8221;1&#8243; collapsible=&#8221;yes&#8221; type=&#8221;custom&#8221; skin=&#8221;light&#8221;][vc_accordion_tab title=&#8221;Discription&#8221; show_icon=&#8221;yes&#8221; [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1809","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/pages\/1809","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/comments?post=1809"}],"version-history":[{"count":11,"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/pages\/1809\/revisions"}],"predecessor-version":[{"id":2493,"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/pages\/1809\/revisions\/2493"}],"wp:attachment":[{"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/media?parent=1809"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}