{"id":1763,"date":"2024-01-28T20:45:21","date_gmt":"2024-01-28T19:45:21","guid":{"rendered":"https:\/\/www.kowotest.de\/densorapid-d\/"},"modified":"2024-05-17T12:34:59","modified_gmt":"2024-05-17T10:34:59","slug":"densorapid-d","status":"publish","type":"page","link":"https:\/\/www.kowotest.de\/en\/densorapid-d\/","title":{"rendered":"DENSORAPID D"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1703690328020{background-color: rgba(140,150,157,0.2) !important;*background-color: rgb(140,150,157) !important;}&#8221; conditional_render=&#8221;%5B%7B%22value_role%22%3A%22administrator%22%7D%5D&#8221;][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_column_text]<\/p>\n<h3><span style=\"color: #005eb8;\"><strong><span style=\"font-size: 26px;\">DENSORAPID D<\/span><\/strong><\/span><\/h3>\n<p>[\/vc_column_text][vc_column_text]<span style=\"color: #8c969d;\"><strong>Article No.: 13 4054X<\/strong><\/span><\/p>\n<p><span style=\"color: #8c969d;\">Transmission Densitometer<br \/>\naccording to ISO 5, ISO 14807, ASTM E1079<\/span><\/p>\n<p><span style=\"color: #8c969d;\">For precise determination<br \/>\nof optical densities of X-ray films<\/span>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_gallery interval=&#8221;3&#8243; images=&#8221;1548,1549,1547&#8243; img_size=&#8221;full&#8221; onclick=&#8221;img_link_large&#8221; custom_links_target=&#8221;_blank&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][vc_accordion active_tab=&#8221;1&#8243; collapsible=&#8221;yes&#8221; type=&#8221;custom&#8221; skin=&#8221;light&#8221;][vc_accordion_tab title=&#8221;Discription&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<h4>DENSORAPID D Transmission Densitometer, hand held<\/h4>\n<p>For precise determination of optical densities of X-ray films the DENSORAPID D is equipped with innovative digital measuring technique.<br \/>\nThe illuminated display enables easy readings even in darkened rooms and calibration of the instrument, done with the software, is simple and much more accurate than on conventional densitometers.<br \/>\nFault-free measurements even in slightly inclined positions are guaranteed by the ergonomic hand probe with a soft tip avoiding scratches on the film.<br \/>\nThe battery is charged with a standard USB charger and ensures an operating time of more than 100 hours with display illumination switched off.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=&#8221;Specification&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<table style=\"height: 491px;\" width=\"531\">\n<tbody>\n<tr>\n<td width=\"199\">Housing:<\/td>\n<td width=\"219\">ABS plastics, IP 65<\/td>\n<\/tr>\n<tr>\n<td>Hand probe:<\/td>\n<td>Aluminum, anodized<\/td>\n<\/tr>\n<tr>\n<td>Measuring range:<\/td>\n<td>D 0.00 \u2026 &gt; 5.00<\/td>\n<\/tr>\n<tr>\n<td>Resolution:<\/td>\n<td>D 0.01<\/td>\n<\/tr>\n<tr>\n<td>Accuracy:<\/td>\n<td>+\/- D 0.03<\/td>\n<\/tr>\n<tr>\n<td>Repeatability:<\/td>\n<td>+\/- D 0.02<\/td>\n<\/tr>\n<tr>\n<td>Aperture size:<\/td>\n<td>\u00d8 2.0 mm<\/td>\n<\/tr>\n<tr>\n<td>Communication port:<\/td>\n<td>USB 2.0, Micro USB<\/td>\n<\/tr>\n<tr>\n<td>Battery operating time:<\/td>\n<td>100 hours (illumination off)<\/td>\n<\/tr>\n<tr>\n<td>USB Charger:<\/td>\n<td>100 \u2026 240 V, 50 \u2026 60 Hz, Micro USB<\/td>\n<\/tr>\n<tr>\n<td>Dimensions unit:<\/td>\n<td>135 x 73 x 29 mm (LxWxH)<\/td>\n<\/tr>\n<tr>\n<td>Dimensions probe:<\/td>\n<td>\u00d8 14 x 120 mm (\u00d8xL), cable 1 m<\/td>\n<\/tr>\n<tr>\n<td>Dimensions case: :<\/td>\n<td>325 x 270 x 55 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight unit:<\/td>\n<td>0.25 kg<\/td>\n<\/tr>\n<tr>\n<td>Weight total with case:<\/td>\n<td>0.90 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][vc_column_text]Required measuring light source &#8211; Film viewer:<\/p>\n<table style=\"height: 83px;\" width=\"531\">\n<tbody>\n<tr>\n<td width=\"199\">Color temperature:<\/td>\n<td width=\"219\">ca. 2,800 \u2026 5,000 K<\/td>\n<\/tr>\n<tr>\n<td>Luminance:<\/td>\n<td>ca. 70,000 \u2026 100,000 cd\/m\u00b2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=&#8221;Types&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text]<strong>Types:<\/strong>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_column_text]<strong>Article No.:<\/strong>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text]DENSORAPID D Densitometer<br \/>\ncomplete with:<br \/>\n[\/vc_column_text][vc_column_text]USB Charger [\/vc_column_text][vc_column_text]Transport case<br \/>\n[\/vc_column_text][vc_column_text]Measuring mask, magnetic, 10&#215;24 cm \/ \u00d8 10 mm [\/vc_column_text][vc_column_text]KOWOSTEP D Density step tablet[\/vc_column_text][vc_column_text]7 density values, &gt;0,30 \u2026 &gt;5,00<br \/>\nRe-calibration interval 3 years<br \/>\nTest certificates, Certificates of Conformity[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_column_text]13 40540[\/vc_column_text][vc_empty_space height=&#8221;28px&#8221;][vc_column_text]13 40546[\/vc_column_text][vc_column_text]13 40547[\/vc_column_text][vc_column_text]13 40104[\/vc_column_text][vc_column_text]13 40207[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=&#8221;Accessories&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner][vc_column_text]You can find accessories on the leaflet[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=&#8221;Leaflets&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner][vc_column_text css=&#8221;&#8221;]leaflet German: <a href=\"https:\/\/www.kowotest.de\/wp-content\/uploads\/2024\/02\/DENSORAPID-D_02_DE.pdf\">DENSORAPID D<\/a><br \/>\nleaflet English: <a href=\"https:\/\/www.kowotest.de\/wp-content\/uploads\/2024\/02\/DENSORAPID-D_03_EN.pdf\">DENSORAPID D<\/a>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][\/vc_accordion][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1703690328020{background-color: rgba(140,150,157,0.2) !important;*background-color: rgb(140,150,157) !important;}&#8221; conditional_render=&#8221;%5B%7B%22value_role%22%3A%22administrator%22%7D%5D&#8221;][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_column_text] DENSORAPID D [\/vc_column_text][vc_column_text]Article No.: 13 4054X Transmission Densitometer according to ISO 5, ISO 14807, ASTM E1079 For precise determination of optical densities of X-ray films[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_gallery interval=&#8221;3&#8243; images=&#8221;1548,1549,1547&#8243; img_size=&#8221;full&#8221; onclick=&#8221;img_link_large&#8221; custom_links_target=&#8221;_blank&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][vc_accordion active_tab=&#8221;1&#8243; collapsible=&#8221;yes&#8221; type=&#8221;custom&#8221; skin=&#8221;light&#8221;][vc_accordion_tab title=&#8221;Discription&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner][vc_column_text] DENSORAPID D Transmission Densitometer, hand held For [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1763","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/pages\/1763","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/comments?post=1763"}],"version-history":[{"count":10,"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/pages\/1763\/revisions"}],"predecessor-version":[{"id":2360,"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/pages\/1763\/revisions\/2360"}],"wp:attachment":[{"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/media?parent=1763"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}