{"id":1654,"date":"2024-01-28T19:28:01","date_gmt":"2024-01-28T18:28:01","guid":{"rendered":"https:\/\/www.kowotest.de\/cr-phantom-6x10\/"},"modified":"2024-05-17T12:46:31","modified_gmt":"2024-05-17T10:46:31","slug":"cr-phantom-6x10","status":"publish","type":"page","link":"https:\/\/www.kowotest.de\/en\/cr-phantom-6x10\/","title":{"rendered":"CR Phantom 6&#215;10"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1703690328020{background-color: rgba(140,150,157,0.2) !important;*background-color: rgb(140,150,157) !important;}&#8221; conditional_render=&#8221;%5B%7B%22value_role%22%3A%22administrator%22%7D%5D&#8221;][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_column_text]<\/p>\n<h3><span style=\"color: #005eb8;\"><strong><span style=\"font-size: 26px;\">CR PHANTOM 6&#215;10<\/span><\/strong><\/span><\/h3>\n<p>[\/vc_column_text][vc_column_text]<span style=\"color: #8c969d;\"><strong>Article No.: 11 00218<\/strong><\/span><\/p>\n<p><span style=\"color: #8c969d;\">according to ISO 16371-1, ASTM E2445<\/span><\/p>\n<p><span style=\"color: #8c969d;\">Smaller, simpler CR Phantom<br \/>\nfor Qualification of CR Systems<br \/>\nProcess Control and Long-Term-Stability<\/span>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_gallery interval=&#8221;3&#8243; images=&#8221;1544,1416,1545&#8243; img_size=&#8221;full&#8221; onclick=&#8221;img_link_large&#8221; custom_links_target=&#8221;_blank&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][vc_accordion active_tab=&#8221;1&#8243; collapsible=&#8221;yes&#8221; type=&#8221;custom&#8221; skin=&#8221;light&#8221;][vc_accordion_tab title=&#8221;Discription&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner][vc_column_text css=&#8221;&#8221;]<\/p>\n<h4>Test Phantom for Qualification of Image Plate Scanner Systems (CR)<\/h4>\n<p>CR Phantom enables to test all relevant parameters of CR Scanner systems and Imaging Plates (IP) like Basic Spatial Resolution, MTF, Contrast Sensitivity, Blooming, Laser Jitter, Scanner Slippage, Shading, Erasure and more. These tests required and described in detail in standards ASTM E2445 and ISO 16371-1 have to be performed periodically for checking process control and long-term-stability.<\/p>\n<p>The KOWOTEST CR Phantoms exceed these standards by including two Duplex Wire Type IQIs and measuring points for Shading in both axes &#8211; portrait and landscape. All required information is mapped on the Imaging Plate with a single X-ray exposure. Phantom must not be rotated to generate information of second axis. This results in higher accuracy and significant time savings.<\/p>\n<p>CR Phantom 6&#215;10 is designed for use of smaller Imaging Plates. Even IPs in weld formats down to 10&#215;24 cm can be used to perform all essential tests.<br \/>\nFor Linearity check in landscape direction additional tungsten balls in a graduation of 25 mm are available. The Duplex Wire Type IQIs can be removed to use for other applications.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=&#8221;Specification&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<table style=\"height: 420px;\" width=\"1207\">\n<tbody>\n<tr>\n<td width=\"30\"><\/td>\n<td width=\"135\">IQI, Gauge<\/td>\n<td width=\"233\"> Test, Check<\/td>\n<td width=\"62\">Deviation<\/td>\n<td width=\"177\">Difference<\/td>\n<\/tr>\n<tr>\n<td>A<\/td>\n<td>T-Target Laser<\/td>\n<td>Jitter, MTF, PMT Non-Linearity<\/td>\n<td>smaller<\/td>\n<td>equal tests feasible<\/td>\n<\/tr>\n<tr>\n<td>B<\/td>\n<td>Duplex Wire Type IQI<\/td>\n<td>Basic Spatial Resolution, Unsharpness<\/td>\n<td>optional<\/td>\n<td>D13, D15, D17 to be inserted<\/td>\n<\/tr>\n<tr>\n<td>C<\/td>\n<td>BAM Snail<\/td>\n<td>Central Beam Alignment<\/td>\n<td>no<\/td>\n<td>no<\/td>\n<\/tr>\n<tr>\n<td>D<\/td>\n<td>Line Pair Gauge<\/td>\n<td>Resolution<\/td>\n<td>missing<\/td>\n<td>test preferably done with Duplex IQI<\/td>\n<\/tr>\n<tr>\n<td>E<\/td>\n<td>Shading IQI<\/td>\n<td>Shading<\/td>\n<td>closer<\/td>\n<td>equal tests feasible<\/td>\n<\/tr>\n<tr>\n<td>F<\/td>\n<td>Cassette Position Locator<\/td>\n<td>Position of IP<\/td>\n<td>missing<\/td>\n<td>none-essential<\/td>\n<\/tr>\n<tr>\n<td>G<\/td>\n<td>Homogeneous Strip Target<\/td>\n<td>Scanner Slippage<\/td>\n<td>smaller<\/td>\n<td>equal tests feasible<\/td>\n<\/tr>\n<tr>\n<td>H<\/td>\n<td>Lucite Plate<\/td>\n<td>Carrier Plate<\/td>\n<td>smaller<\/td>\n<td>equal tests feasible<\/td>\n<\/tr>\n<tr>\n<td>I<\/td>\n<td>Linearity IQI &#8211; cm-\/ inch Ruler<\/td>\n<td>Spatial Linearity, Distortion<\/td>\n<td>cm only<\/td>\n<td>equal tests feasible<\/td>\n<\/tr>\n<tr>\n<td>I<\/td>\n<td>Tungsten Balls, \u00d8 1.5 mm<\/td>\n<td>Spatial Linearity, Distortion<\/td>\n<td>additional<\/td>\n<td>for IP width less than 15 cm (6 inch)<\/td>\n<\/tr>\n<tr>\n<td>J<\/td>\n<td>Contrast Sensitivity Gauge<\/td>\n<td>Contrast Sensitivity<\/td>\n<td>Cu missing<\/td>\n<td>none-essential, Cu not penetrated at 90 kV<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Dimensions:<\/td>\n<td>250 x 160 x 16,5 mm<\/td>\n<td>6 x 10 x 0.65 inch<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=&#8221;Types&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text]<strong>Types:<\/strong>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_column_text]<strong>Article No.:<\/strong>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text]CR Phantom 6&#215;10 &#8211; Type I in wooden case<br \/>\nDuplex Wire Type IQIs not included but required (optional)<br \/>\nTest Certificates acc. to ASTM E2445, ISO 16371-1<br \/>\nDeclaration of Conformity acc. to EN ISO\/ IEC 17050-1\/ -2[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_column_text]11 00218[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=&#8221;Accessories&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner][vc_column_text]You can find accessories on the leaflet[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][vc_accordion_tab title=&#8221;Leaflets&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner][vc_column_text css=&#8221;&#8221;]leaflet German:<br \/>\nleaflet English: <a href=\"https:\/\/www.kowotest.de\/wp-content\/uploads\/2024\/05\/CR-Phantom_Type-I_6x10_01_EN.pdf\">CR PHANTOM 6&#215;10<\/a>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_accordion_tab][\/vc_accordion][vc_empty_space][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1703690328020{background-color: rgba(140,150,157,0.2) !important;*background-color: rgb(140,150,157) !important;}&#8221; conditional_render=&#8221;%5B%7B%22value_role%22%3A%22administrator%22%7D%5D&#8221;][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_column_text] CR PHANTOM 6&#215;10 [\/vc_column_text][vc_column_text]Article No.: 11 00218 according to ISO 16371-1, ASTM E2445 Smaller, simpler CR Phantom for Qualification of CR Systems Process Control and Long-Term-Stability[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_empty_space][vc_gallery interval=&#8221;3&#8243; images=&#8221;1544,1416,1545&#8243; img_size=&#8221;full&#8221; onclick=&#8221;img_link_large&#8221; custom_links_target=&#8221;_blank&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space][vc_accordion active_tab=&#8221;1&#8243; collapsible=&#8221;yes&#8221; type=&#8221;custom&#8221; skin=&#8221;light&#8221;][vc_accordion_tab title=&#8221;Discription&#8221; show_icon=&#8221;yes&#8221; icon=&#8221;fas fa-angle-down&#8221;][vc_row_inner][vc_column_inner][vc_column_text css=&#8221;&#8221;] Test Phantom for Qualification of [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1654","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/pages\/1654","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/comments?post=1654"}],"version-history":[{"count":10,"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/pages\/1654\/revisions"}],"predecessor-version":[{"id":2371,"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/pages\/1654\/revisions\/2371"}],"wp:attachment":[{"href":"https:\/\/www.kowotest.de\/en\/wp-json\/wp\/v2\/media?parent=1654"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}